Home ProductsFan Coil Motor

FCU Customized Motor - 90W 1000RPM/3SPD 240V 60HZ

FCU Customized Motor - 90W 1000RPM/3SPD 240V 60HZ

  • FCU Customized Motor - 90W 1000RPM/3SPD 240V 60HZ
  • FCU Customized Motor - 90W 1000RPM/3SPD 240V 60HZ
  • FCU Customized Motor - 90W 1000RPM/3SPD 240V 60HZ
  • FCU Customized Motor - 90W 1000RPM/3SPD 240V 60HZ
FCU Customized Motor - 90W 1000RPM/3SPD 240V 60HZ
Product Details:
Place of Origin: Changzhou, China
Brand Name: trusTec
Certification: CE、UL529388
Model Number: YDK-90-6B60-PJN
Payment & Shipping Terms:
Minimum Order Quantity: 200 pcs
Price: Negotiable (FOB/CNF/CIF)
Packaging Details: Standard carton packing, foam board inside for protection.
Delivery Time: 15 days fresh products after order confirmation.
Payment Terms: T/T, L/C
Supply Ability: 100,000 pcs per month
Contact Now
Detailed Product Description
Product: HVAC Blower Motor Supply Voltage: 240V
Motor Type: Permanent Split Capacitor Supply Frequency: 60Hz
Enclosure Type: OAO(Open Air Over) Current: 3A
Thermal Overload: Equipped With An Automatic Thermal Overload Output HP: 90W
Phase: Single Phase Speed: 1000RPM/3SPD
Shaft Flat: One Flat Capacitor: 5.0μF/370V
Mounting Orientation: All Angle Pole: 6P
Insulation Class: Class B Shaft Diameter: 12.7mm/0.5"
Bearings: Ball Bearing PF: 0.9
Rotation: CW Shaft Length: 130mm/5.12"
Flat Length: 80mm/3.15" Max. Ambient Temperature: 40℃/104℉
Lead Length: 700mm/27.56" Motor Shell Length: 98mm/3.86"

5-Step Selection Methodology

Step 1: Match Electrical Specifications (The Non-Negotiables)

First, locate the nameplate on your existing motor. This is your most important source of truth. You must verify:

  • Voltage & Phase: Common voltages are 115V or 230V, single-phase. Warning: Operating a motor on incorrect voltage will cause it to burn out.

  • Horsepower (HP) or Wattage: The replacement motor must have an equal or slightly higher rating. Use conversion: 1 HP ≈ 746 Watts.

  • RPM (Speed): Match the full-load RPM exactly (e.g., 1075 RPM). A different speed will drastically affect airflow and system balance.

  • Amperage (FLA): The new motor's Full Load Amps should be equal to or greater than the original.

  • Frequency (Hz): Match your power supply (60Hz in North America, 50Hz elsewhere).

Step 2: Verify Physical Dimensions & Mounting

A motor that doesn't fit physically cannot be installed. Check:

  • Frame Size & Type: This standardizes dimensions (e.g., 42 Frame, 48 Frame). Match it exactly.

  • Shaft Specifications: Measure the diameter (common: 1/2" or 12.7mm), length, and check for a keyway.

  • Mounting Bracket/Holes: Ensure the bolt hole pattern matches your FCU housing.

  • Rotation Direction: Confirm if you need Clockwise (CW) or Counter-Clockwise (CCW) rotation. Many motors are reversible.

Step 3: Choose Your Motor Technology: PSC vs. EC

This choice impacts efficiency, control, and cost.

Table 1: Motor Technology Comparison

 
 
Feature PSC Motor (Permanent Split Capacitor) EC Motor (Electronically Commutated)
Efficiency Standard Premium - Up to 70% more efficient
Speed Control Fixed Taps (e.g., 3-Speed) Infinitely Variable & Programmable
Primary Use Case Direct, cost-effective replacement Energy savings, modern comfort, smart building systems
Retrofit Complexity Simple plug-and-play May require control system compatibility check (0-10V, PWM)
Lifetime Cost Higher (energy + maintenance) Lower total cost of ownership
Noise Level Generally higher at full speed Typically quieter across speed range

 

Note: EC motors offer superior reliability with a brushless design and precise control, but ensure your FCU's existing controls are compatible.

Step 4: Determine Speed & Control Requirements

  • Multi-Speed (PSC): The traditional option. Your existing wiring will have leads for High, Medium, Low speeds.

  • Variable Speed (EC): Provides ultimate comfort and quiet operation by adjusting airflow continuously. Ideal for zones with varying demand.

Step 5: Final Pre-Installation Verification Checklist

Before purchasing and installing, confirm all items below:

  • Electrical Specs (V, HP, RPM, A, Hz) are matched.

  • Physical Dimensions (Frame, Shaft, Mounting) are compatible.

  • Motor Technology (PSC or EC) is selected per project needs.

  • For PSC Motors: A new, correct capacitor (µF & Voltage) is procured.

  • Thermal Protection: Motor includes built-in overload protection.

  • Safety Certifications: Motor carries relevant marks (e.g., UL, cUL, CE).

  • Wiring Diagram for the new motor is available for installation.


2. Expert Tips & Common Mistakes to Avoid

 
 
Do's Don'ts
✅ Use the new motor's nameplate as the primary guide. ❌ Guess on RPM or use a "close enough" speed.
Always replace the capacitor when installing a new PSC motor. ❌ Reuse the old capacitor.
✅ Follow the new motor's wiring diagram precisely. ❌ Assume wiring is identical to the old motor.
✅ For noise-sensitive areas, check the motor's sound rating (sones/dB). ❌ Overlook physical clearances for capacitors or conduit boxes.
✅ For EC motor retrofits, verify control signal compatibility first. ❌ Assume an EC motor is a direct plug-and-play swap without checking controls.

3. Conclusion & Next Steps

A methodical approach to FCU motor selection prevents downtime, ensures safety, and optimizes energy use. For complex retrofits, especially involving EC technology, consulting with the FCU manufacturer or a qualified HVAC technician is strongly recommended.